MAINTENANCE
GENERAL RECOMMENDATIONS
The warranty of the generator does not cover items that
have been subjected to operator abuse or negligence.
To receive full value from the warranty, operator must
maintain the generator as instructed in this manual.
ENGINE MAINTENANCE
Refer to the Engine Operator's manual for service and
maintenance of the engine.
GENERATOR MAINTENANCE
Your generator should be kept clean and dry at all
times. The generator should not be stored or operated
in environments that includes excessive moisture, dust
or any corrosive vapors. If these substances are on the
generator, clean with a cloth or soft bristle brush. Do not
use a garden hose or anything with water pressure to
clean the generator. Water may enter the cooling air
slots and could possibly damage the rotor, stator and
the internal windings of the gen head.
(if equipped) Ground Fault Circuit Interrupter
GFCI receptacle)
MONTHLY: For maximum protection against electrical
shock the GFCI should be tested monthly.
To test:
1. Depress the TEST button. The RESET button should
extend. If the RESET button does not extend, notify
a DeVilbiss Air Power Company Authorized Warranty
Service Center.
2. To restore power, depress the RESET button firmly
into the GFCI unit until an audible click is heard. If
reset properly, the RESET button is flush with the
surface of the test button. When the button stays in,
the power is ON.
Note 1: Change oil after first two (2) operating hours and every 50 operating hours thereafter, more often if operated in
extreme dusty or dirty conditions.
Note 2: Check oil after 5 hours of operation
CUSTOMER RESPONSIBILITIES TABLE
MAINTENANCE TASK
Before each
use
X
Every 25
Hours of Every
Season
See Note 2
X
X
Every 50
Hours of Every
Season
See Note 1
Every 100
Hours of Every
Season
X
Check oil level
Change oil
Clean Air Filter Assembly
Check Spark Plug
Prepare Unit for Storage
Prepare unit for storage if it is to remain idle for more than 30 days.
CONNECTING PROCEDURE FOR RAISING OR
SUSPENDING GENERATORS EQUIPPED WITH
LIFT RINGS
Failure to properly connect lifting cables, chains,
or straps can cause property damage, serious
injury or death, and void the manufacturer's
warranty.
Always use cables, chains, or straps rated at 2000
lbs. working load or more to raise or suspend gen-
erator.
Never operate generator while suspended. This
could cause property damage, serious injury or
death.
Lift Ring
Lift Ring
1. Route cable, chain, or strap through both lift rings as
shown. ALWAYS use both lift rings when raising or sus-
pending generator.
Make sure the generator is in a level position
before raising or suspending to prevent damage.